382 XgOS User’s Guide September 2014
Note The space following the equals sign (=) is mandatory.
This command causes the service to delay its start until LUNs are available across
the vHBA. For the details of the XgDependRoot service, see “Xsigo Dependency
Service” on page 384.
Upgrading Windows HCA Firmware and
Option ROM
XgOS supports the following firmware levels:
InfiniHost Single Port HCA: 1.2.0
InfiniHost Dual Port HCA: 5.3.0
ConnectX and ConnectX-2: 2.7.0 and later
When the Xg_FWUpdate.vbs script runs, it first checks the current HCA Device ID
and firmware level and determines if an update is required.
1.
To run the script, start a command prompt by following Start->Run....
2. Change directory to %programfiles%\Xsigo Systems\Support\
FirmwareUpdate.
This is the directory where the HCA firmware update script is located.
3. From the prompt, run the script by issuing the following command:
cd %programfiles%\Xsigo Systems\Support\FirmwareUpdate
cscript Xg_FWUpdate.vbs
Microsoft (R) Windows Script Host Version 5.6
Copyright (C) Microsoft Corporation 1996-2001. All rights
reserved.
:
#################################################################
# Main Menu
#################################################################
Selected HCA Card Number: 0
HCA Device ID : mt25218_pciconf0
Image Type : failsafe
I.S. Version : 1
Device ID :
Chip Revision : a0
Vista de pagina 407