AMD LE-363 User's Guía de usuario Pagina 408

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 436
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 407
382 XgOS User’s Guide • September 2014
Note – The space following the equals sign (=) is mandatory.
This command causes the service to delay its start until LUNs are available across
the vHBA. For the details of the XgDependRoot service, see “Xsigo Dependency
Service” on page 384.
▼ Upgrading Windows HCA Firmware and
Option ROM
XgOS supports the following firmware levels:
■ InfiniHost Single Port HCA: 1.2.0
■ InfiniHost Dual Port HCA: 5.3.0
■ ConnectX and ConnectX-2: 2.7.0 and later
When the Xg_FWUpdate.vbs script runs, it first checks the current HCA Device ID
and firmware level and determines if an update is required.
1.
To run the script, start a command prompt by following Start->Run....
2. Change directory to %programfiles%\Xsigo Systems\Support\
FirmwareUpdate.
This is the directory where the HCA firmware update script is located.
3. From the prompt, run the script by issuing the following command:
cd %programfiles%\Xsigo Systems\Support\FirmwareUpdate
cscript Xg_FWUpdate.vbs
Microsoft (R) Windows Script Host Version 5.6
Copyright (C) Microsoft Corporation 1996-2001. All rights
reserved.
:
#################################################################
# Main Menu
#################################################################
Selected HCA Card Number: 0
HCA Device ID : mt25218_pciconf0
Image Type : failsafe
I.S. Version : 1
Device ID :
Chip Revision : a0
Vista de pagina 407
1 2 ... 403 404 405 406 407 408 409 410 411 412 413 ... 435 436

Comentarios a estos manuales

Sin comentarios